Vista de pagina 46
StorageWorks SCSI Buses
5.3 SBB Shelf SCSI Bus Configurations
5.3 SBB Shelf SCSI Bus Configurations
Prior to shipment, the SBB shelf SCSI buses are configured to meet system
requirements in one of the following ways:
A single bus with seven device addresses (seven SBBs maximum) on one shelf
Two buses with four device addresses on one bus (four SBBs maximum) and
three device addresses on the other (three SBBs maximum)
A single bus with seven device addresses (seven SBBs maximum) on multiple
shelves
A customer can configure buses provided that the rules listed in the following
sections are strictly observed. For a complete listing of compatible SCSI cables,
see the StorageWorks Family Configuration Guide.
Note
The length of a shelf SCSI bus is the distance from the input connector to
the terminator on the shelf.
Table 5-3 lists the standard factory SCSI bus configurations and defines the bus
lengths.
Table 5–3 StorageWorks Bus Lengths
Shelf Bus Input Slot 1 Slot 5 Meters Feet
Single Shelf—Single Bus
1 1 JA1 Terminator Jumper 0.9 2.9
J
0123456
POWER
CXO-3596B-MC
7-DEVICE BUS INPUT
T
BUS LENGTH: 0.9 m (34.7 in)
JA1
JB1
(7)
Single Shelf—Two Buses
1 1 JA1 Jumper† Terminator 0.4 1.4
1 2 JB1 Jumper† Terminator 0.6 2.0
T
0
1
23456
POWER
CXO-3597B-MC
3-DEVICE BUS INPUT
4-DEVICE BUS INPUT
J
BUS LENGTH: 0.4 m (16.4 in)
JA1
JB1
BUS LENGTH: 0.6 m (23.6 in)
(7)
The jumper is placed here for safekeeping and has no effect on the SCSI bus.
From input connector (JA1) to output connector (JB1)
§ Do not install a terminator here.
(continued on next page)
StorageWorks SCSI Buses 5–5
Vista de pagina 46