Digital Equipment Corporation RAID Array 3000 storage subsystem Guía de usuario

Busca en linea o descarga Guía de usuario para Los controladores raid Digital Equipment Corporation RAID Array 3000 storage subsystem. Digital Equipment Corporation RAID Array 3000 storage subsystem User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 94
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
RAID Array 3000 Storage
Subsystem
Hardware User’s Guide
EK–SMCPO–UG. A01
Digital Equipment Corporation
Maynard, Massachusetts
Vista de pagina 0
1 2 3 4 5 6 ... 93 94

Indice de contenidos

Pagina 1 - Subsystem

RAID Array 3000 StorageSubsystemHardware User’s GuideEK–SMCPO–UG. A01Digital Equipment CorporationMaynard, Massachusetts

Pagina 3 - Contents

EK–SMCPO–UG. A01xiAbout This GuideThis section identifies the audience of this guide and describes the contents (chapter-by-chapter) and structure. In

Pagina 4 - 3 Maintenance

RAID Array 3000 Pedestal EnclosurexiiEK–SMCPO–UG. A01Chapter 4: Expansion Pedestal OptionExpansion Pedestal Option describes the major features and ch

Pagina 5 - 5 Second Controller Option

About This GuideEK–SMCPO–UG. A01xiiiConventions (continued)Table 3 Nomenclature ConventionRAID Advisory Board Description RAID Array 3000 UsageRAID 0

Pagina 6 - Figures (continued)

RAID Array 3000 Pedestal EnclosurexivEK–SMCPO–UG. A01Who to contact in EuropeInformation and Product Questions: Contact the DIGITAL Distributor or res

Pagina 7 - EK–SMCPO–UG. A01 vii

EK–SMCPO–UG. A01 1–11Product OverviewThis chapter provides an overall description of the RAID Array 3000 storage subsystemand its components. A list o

Pagina 8

RAID Array 3000 Storage Subsystem1–2 EK–SMCPO–UG. A01The RAID Array 3000 pedestal enclosure and its associated options are listedand described in Tabl

Pagina 9 - Revision Record

Chapter 1. Product OverviewEK–SMCPO–UG. A01 1–3Table 1–1 Pedestal RAID Array 3000 Part Numbers and Model DescriptionsDIGITAL Part No. Item Descriptio

Pagina 10

RAID Array 3000 Storage Subsystem1–4 EK–SMCPO–UG. A011.2 Pedestal FeaturesThe major features of the pedestal are:• Two differential 16-bit UltraSCSI h

Pagina 11 - About This Guide

Chapter 1. Product OverviewEK–SMCPO–UG. A01 1–5 Figure 1–2 Pedestal Front Panel Major Components Figure 1–3 Pedestal Rear Panel Power Supplies

Pagina 12 - Conventions

First Edition, January 1998The disclosure of this information does not grant to the user a license under any patents,pending patents, trademarks, or c

Pagina 13 - Support and Services

RAID Array 3000 Storage Subsystem1–6 EK–SMCPO–UG. A011.4 Pedestal Components The major components in the pedestal subsystem include:• Dual-channel RAI

Pagina 14 - Who to contact in Europe

Chapter 1. Product OverviewEK–SMCPO–UG. A01 1–7• Per LUN write cache/write back selection• Configuration/Maintenance via RS-232 or host SCSI channel u

Pagina 15 - Product Overview

RAID Array 3000 Storage Subsystem1–8 EK–SMCPO–UG. A01 1.4.5 Environmental Monitor Unit (EMU) The EMU is an internal circuit board that monitors the o

Pagina 16 - 1–2 EK–SMCPO–UG. A01

Chapter 1. Product OverviewEK–SMCPO–UG. A01 1–9Figure 1–5 Pedestal Rear Panel Components3000-23AController (Bottom)Controller (Top)Host #1ExternalFau

Pagina 17 - Chapter 1. Product Overview

RAID Array 3000 Storage Subsystem1–10 EK–SMCPO–UG. A01Figure 1–6 UltraSCSI Bus Port and Default SCSI ID AssignmentsID9ID9ID 11ID8ID8ID10ID10Top Contr

Pagina 18 - 1.3 Pedestal Cabinet

Chapter 1. Product OverviewEK–SMCPO–UG. A01 1–11Figure 1–7 UltraSCSI Bus Configuration Switch3000-386Figure 1–8 Slot Locations and SCSI ID Addresses

Pagina 19

RAID Array 3000 Storage Subsystem1–12 EK–SMCPO–UG. A011.5 SpecificationsTable 1–2 Pedestal Technical SpecificationsTechnical SpecificationsItem Desc

Pagina 20 - 1.4.2 RAID Array Controller

Chapter 1. Product OverviewEK–SMCPO–UG. A01 1–13Table 1–3 Pedestal Physical and Power SpecificationsPhysical SpecificationsItem DimensionHeight 564 m

Pagina 22 - 1–8 EK–SMCPO–UG. A01

EK–SMCPO–UG. A01 2–12RAID Array ControllerThis chapter describes the major features and characteristics of the RAID array control-ler in the RAID Arra

Pagina 23 - 1.4.6 UltraSCSI Buses

EK–SMCPO–UG. A01 iiiContentsRevision Record ...ixAbout This

Pagina 24 - 1–10 EK–SMCPO–UG. A01

RAID Array 3000 Pedestal Enclosure2–2 EK–SMCPO–UG. A01There are two configurations for redundant pairs of controllers: Active/ActiveFailover mode and

Pagina 25

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–3From the pedestal’s perspective, the controller receives the I/O requests from thehost and directs

Pagina 26 - 1.5 Specifications

RAID Array 3000 Pedestal Enclosure2–4 EK–SMCPO–UG. A01• Stripesets (RAID 0) combine disk drives in serial to increase transfer or re-quests rates• Mir

Pagina 27

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–5 Table 2–1 Controller Specifications (Continued) Item Specifications Disk Warm Spare (not spinn

Pagina 28

RAID Array 3000 Pedestal Enclosure2–6 EK–SMCPO–UG. A01 2.3 Controller Reset and LED Indicators Figure 2–3 illustrates the front panel of the controll

Pagina 29 - RAID Array Controller

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–7 Figure 2–3 Controller Front Panel 2.4 Flexible RAID Set Configuration In addition to its flexi

Pagina 30 - 2.2 Controller Features

RAID Array 3000 Pedestal Enclosure2–8 EK–SMCPO–UG. A01• Each RAID set can be partitioned into smaller redundancy groups.• The controller’s host LUN Ma

Pagina 31 - EK–SMCPO–UG. A01 2–3

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–9The controller uses several techniques to streamline write operations and signifi-cantly improve p

Pagina 32

RAID Array 3000 Pedestal Enclosure2–10 EK–SMCPO–UG. A012.6 RAID Levels SupportedThe RAID Array 3000 controller supports the following RAID levels:Tabl

Pagina 33 - EK–SMCPO–UG. A01 2–5

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–112.6.1 RAID 0RAID 0 breaks up data into smaller chunks and writes each chunk to a differentdrive

Pagina 34 - 2–6 EK–SMCPO–UG. A01

RAID Array 3000 Storage Subsystemiv EK–SMCPO–UG. A012 RAID Array Controller (continued)2.6.5 RAID 5...

Pagina 35 - EK–SMCPO–UG. A01 2–7

RAID Array 3000 Pedestal Enclosure2–12 EK–SMCPO–UG. A01Figure 2–4 RAID 0 Write

Pagina 36 - 2.5.1 Custom Components

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–132.6.2 RAID 1RAID 1 (also known as mirroring or shadowing) takes data sent by the host andduplica

Pagina 37 - EK–SMCPO–UG. A01 2–9

RAID Array 3000 Pedestal Enclosure2–14 EK–SMCPO–UG. A01Figure 2–6 Diagram of RAID 0+1 WriteIn the event of a drive failure, a RAID 0+1 array will ent

Pagina 38 - 2.6 RAID Levels Supported

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–152.6.4 RAID 4RAID 4 breaks up host data into chunks, calculates parity by performing an ex-clusiv

Pagina 39 - 2.6.1 RAID 0

RAID Array 3000 Pedestal Enclosure2–16 EK–SMCPO–UG. A01In the event of a single drive failure, a RAID 4 array will continue to operate indegraded mode

Pagina 40 - Figure 2–4 RAID 0 Write

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–17Figure 2–8 Diagram of a RAID 5 WriteRAID 5 handles drive failures in the same manner as RAID 4,

Pagina 41 - 2.6.3 RAID 0+1

RAID Array 3000 Pedestal Enclosure2–18 EK–SMCPO–UG. A01CAUTIONRAID 5 can withstand a single failure and handleI/O activity without interruption in deg

Pagina 42 - Table 2–5 RAID 0+1 Example

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–19Table 2–6 System ParametersParameter DescriptionPassword Checking Enables or disables password c

Pagina 43 - 2.6.4 RAID 4

RAID Array 3000 Pedestal Enclosure2–20 EK–SMCPO–UG. A012.8 Redundant OperationWhen operating in a redundant configuration, the two controllers are lin

Pagina 44 - 2.6.5 RAID 5

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–21 While downloading the data, the controller responds to I/O by disconnecting (ifallowed) and wait

Pagina 45 - EK–SMCPO–UG. A01 2–17

ContentsEK–SMCPO–UG. A01 v4 Expansion Pedestal Option4.1 Product Description...

Pagina 46 - 2.7 System Parameters

RAID Array 3000 Pedestal Enclosure2–22 EK–SMCPO–UG. A01 WARNING• Slow Alarm• Normal I/O SEVERE• UltraSCSI Alarm• Flushes Cache• Enters Write-Through M

Pagina 47 - Parameter Description

Chapter 2. RAID Array ControllerEK–SMCPO–UG. A01 2–232.9.2.2 Termination VoltageThe controller monitors the incoming termination voltage levels and e

Pagina 48 - 2.8.3 Failover

RAID Array 3000 Pedestal Enclosure2–24 EK–SMCPO–UG. A012.9.3 Temperature Monitoring2.9.3.1 External TemperatureThe controller monitors the external

Pagina 49 - 2.9 Environmental

EK–SMCPO–UG. A01 3–13MaintenanceThis chapter describes how to interpret the status of the LEDs on the pedestal and usethem as a troubleshooting aid du

Pagina 50 - 2.9.2 Voltage Monitoring

RAID Array 3000 Pedestal Enclosure3–2 EK–SMCPO–UG. A013.2 Pedestal Status and power LEDs The pedestal is equipped with two front panel LEDs (see Figur

Pagina 51 - EK–SMCPO–UG. A01 2–23

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–3Table 3–1 Disk Drive SBB Status LEDsActivity LED Fault LED IndicationOn Off Drive is operating properly.Off

Pagina 52 - 2.9.3 Temperature Monitoring

RAID Array 3000 Pedestal Enclosure3–4 EK–SMCPO–UG. A013.5 EMU Error ReportingThe primary function of the EMU is to detect and report conditions that c

Pagina 53 - Maintenance

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–53.6 Replacing Components (FRU's) This section describes how to replace an FRU in the RAID Array 3000 pe

Pagina 54 - 3.3 SBB Status LEDs

RAID Array 3000 Pedestal Enclosure3–6 EK–SMCPO–UG. A01 3.6.2 Replacing an SBB There are two methods for replacing a disk drive SBB with an identical

Pagina 55 - 3.4 Controller LEDs

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–7Figure 3–4 Replacing an SBB3.6.3 Replacing a Power SupplyYou can replace a power supply without affecting

Pagina 56 - 3.5.1 EMU Error Conditions

RAID Array 3000 Storage Subsystemvi EK–SMCPO–UG. A01Figures (continued)3–8 Remove Screw and Panel...

Pagina 57 - EK–SMCPO–UG. A01 3–5

RAID Array 3000 Pedestal Enclosure3–8 EK–SMCPO–UG. A01Figure 3–5 Replacing a Power Supply

Pagina 58 - 3.6.2 Replacing an SBB

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–93.6.4 Replacing the RAID Array ControllerPerform the following procedure to replace the RAID Array controll

Pagina 59 - Figure 3–4 Replacing an SBB

RAID Array 3000 Pedestal Enclosure3–10 EK–SMCPO–UG. A013.6.5 Replacing the EMU BoardWARNINGOnly qualified service personnel should replacethe EMU. Da

Pagina 60 - 3–8 EK–SMCPO–UG. A01

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–11Figure 3–7 Remove Nuts from UPS and External Fault Connectors3000-4910. Align the connectors on the repla

Pagina 61 - EK–SMCPO–UG. A01 3–9

RAID Array 3000 Pedestal Enclosure3–12 EK–SMCPO–UG. A013.6.14 Replacing the UPSProceed as follows to replace the UPS:1. Ensure the UPS power switch

Pagina 62 - 3–10 EK–SMCPO–UG. A01

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–13Table 3–2 SCSI Bus Length and External CablesBus Rate Bus Length Longest DIGITAL CableSpeed MT/s MB/s Mete

Pagina 63 - EK–SMCPO–UG. A01 3–11

RAID Array 3000 Pedestal Enclosure3–14 EK–SMCPO–UG. A01The SCSI bus configuration switch selects the eight (0 – 7) SCSI bus configura-tions in the ped

Pagina 64 - 3.6.14 Replacing the UPS

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–15NOTETo decrease the configuration number: Pressthe upper switch to step the address down one ad-dress at a

Pagina 65 - EK–SMCPO–UG. A01 3–13

RAID Array 3000 Pedestal Enclosure3–16 EK–SMCPO–UG. A01Figure 3–9 Location of SCSI Bus Configuration Switch3000-386Figure 3–10 Configuration Switch6

Pagina 66 - 3–14 EK–SMCPO–UG. A01

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–173.8 Replacing the Controller Memory Cache ModulesThe two memory cache modules in the RAID controller are re

Pagina 67 - EK–SMCPO–UG. A01 3–15

ContentsEK–SMCPO–UG. A01 viiTables1–1 RAID Array 3000 Part Numbers and Model Descriptions...1–31–2 Pedestal Specifications...

Pagina 68 - 3–16 EK–SMCPO–UG. A01

RAID Array 3000 Pedestal Enclosure3–18 EK–SMCPO–UG. A01Figure 3–12 Release Locking ClipsFigure 3–13 Remove Installed SIMM ModulesCAUTIONEnsure the “

Pagina 69 - EK–SMCPO–UG. A01 3–17

Chapter 3. MaintenanceEK–SMCPO–UG. A01 3–195. Installed the two replacement memory modules by aligning the module and con-nector pins (check alignmen

Pagina 70 - 3–18 EK–SMCPO–UG. A01

RAID Array 3000 Pedestal Enclosure3–20 EK–SMCPO–UG. A01Figure 3–15 Pivot Module Down to Secure

Pagina 71 - EK–SMCPO–UG. A01 3–19

EK–SMCPO–UG. A01 4–14Expansion Pedestal OptionThis chapter describes the major features of the Expansion Pedestal Option and how toconnect the option

Pagina 72 - 3–20 EK–SMCPO–UG. A01

RAID Array 3000 Expansion Pedestal4–2 EK–SMCPO–UG. A014.2 Expansion Pedestal CabinetThe expansion pedestal cabinet is a modular free-standing storage

Pagina 73 - Expansion Pedestal Option

Chapter 4. Expansion Pedestal OptionEK–SMCPO–UG. A01 4–3 Figure 4–2 Expansion Pedestal Slot Locations and ID Addresses3000-19AEXPANSION PEDESTALSLOT

Pagina 74 - 4–2 EK–SMCPO–UG. A01

RAID Array 3000 Expansion Pedestal4–4 EK–SMCPO–UG. A01 Figure 4–3 Rear Panel Power Supplies 4.3 Expansion Pedestal Components The expansion pedestal

Pagina 75 - EXPANSION PEDESTAL

Chapter 4. Expansion Pedestal OptionEK–SMCPO–UG. A01 4–5 The EMU (Figure 4–4) is an internal circuit board, which monitors the operationof the pedesta

Pagina 76 - 4–4 EK–SMCPO–UG. A01

RAID Array 3000 Expansion Pedestal4–6 EK–SMCPO–UG. A01The RAID Array 3000 base pedestal is factory-configured for split-bus operation.You must reconfi

Pagina 77 - EK–SMCPO–UG. A01 4–5

Chapter 4. Expansion Pedestal OptionEK–SMCPO–UG. A01 4–7Figure 4–5 Remove Side Cover from Base Pedestal8. Remove the bus terminator from backplane co

Pagina 79 - J16 (see Figure 4–7)

RAID Array 3000 Expansion Pedestal4–8 EK–SMCPO–UG. A01 Figure 4–7 Disconnect SCSI Cable 3000-41Remove SCSI Cable10. Connect jumper cable 17-04166-03

Pagina 80 - 4–8 EK–SMCPO–UG. A01

Chapter 4. Expansion Pedestal OptionEK–SMCPO–UG. A01 4–911. Remove the “knock-out” plate located above the D1 OUT label on the rearpanel of the base p

Pagina 81 - Remove Knockout

RAID Array 3000 Expansion Pedestal4–10 EK–SMCPO–UG. A01Figure 4–10 Connect SCSI Cable ? 3000-43Connect SCSI Cable13. Set the bus configuration switch

Pagina 82 - 4–10 EK–SMCPO–UG. A01

Chapter 4. Expansion Pedestal OptionEK–SMCPO–UG. A01 4–11Figure 4–12 Configuration SwitchFigure 4–13 Reconfigured SCSI Bus Addresses

Pagina 83 - EK–SMCPO–UG. A01 4–11

RAID Array 3000 Expansion Pedestal4–12 EK–SMCPO–UG. A0114. Reinstall the side panel on the base pedestal.15. Connect the HD68-to-HD68 SCSI cable from

Pagina 84 - 4–12 EK–SMCPO–UG. A01

Chapter 4. Expansion Pedestal OptionEK–SMCPO–UG. A01 4–13Figure 4–15 Power Cable Connections3000-50BasePedestalExpansionPedestalUPSConnectorUPSACPowe

Pagina 85 - Figure 4–16

RAID Array 3000 Expansion Pedestal4–14 EK–SMCPO–UG. A01Figure 4–16 Transfer Drives from Base to Expansion PedestalID = 8ID = 9ID = 10ID = 11ID = 12ID

Pagina 86 - 4–14 EK–SMCPO–UG. A01

EK–SMCPO–UG. A01 5–15Second Controller OptionThis chapter describes how to install a second RAID controller in the pedestal. The sec-ond controller pr

Pagina 87 - Second Controller Option

RAID Array 3000 Pedestal Enclosure5–2 EK–SMCPO–UG. A01Figure 5–1 Second Controller Slot Location3000-48SecondControllerSlot5.2 Installation Procedu

Pagina 88 - 5.2 Installation Procedure

Chapter 5. Second Controller OptionEK–SMCPO–UG. A01 5–35. Perform an inventory of the items in the second controller kit. The kit shouldcontain the fo

Pagina 89 - EK–SMCPO–UG. A01 5–3

EK–SMCPO–UG. A01 ixRevision RecordThis Revision Record provides a concise publication history of this guide. It lists therevision levels, release date

Pagina 90 - 5–4 EK–SMCPO–UG. A01

RAID Array 3000 Pedestal Enclosure5–4 EK–SMCPO–UG. A01 Figure 5–3 Pivot Module Down to Seat 8. Remove the existing controller (see Figure 5–4) and i

Pagina 91 - EK–SMCPO–UG. A01 5–5

Chapter 5. Second Controller OptionEK–SMCPO–UG. A01 5–59. Replace the existing controller into the top controller slot in the pedestal andseat it into

Pagina 93 - Reader’s Comments

Reader’s CommentsManual Order Number:EK–SMCPO–UG. A01 RAID Array 3000 Storage Subsystem Hardware User's GuideDigital is committed to providi

Comentarios a estos manuales

Sin comentarios