Digital Equipment Corporation RAID Array 3000 storage subsystem Guía de usuario Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 94
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
RAID Array 3000 Pedestal Enclosure
2–14 EK–SMCPO–UG. A01
Figure 2–6 Diagram of RAID 0+1 Write
In the event of a drive failure, a RAID 0+1 array will enter degraded mode and
continue to operate by substituting the failed drive with its mirror.
When the controller creates a RAID 0+1 set, it first sorts the drives by channel
number and SCSI ID. Then it stripes the data across every other drive and forms
a mirrored pair with the first two drives, another mirrored pair with the second
two drives, and so on. Table 2–5 describes how the controller uses the drives in a
RAID 0+1 set.
Table 2–5 RAID 0+1 Example
Drives Selected Function
Channel 1, ID 0 First member of stripe set.
Channel 1, ID 1 Mirror of channel 1, ID 0
Channel 1, ID 2 Second member of stripe set
Channel 2, ID 0 Mirror of channel 1, ID 2
Channel 2, ID 1 Third member of stripe set
Channel 2, ID 2 Mirror of channel 2, ID 1